Explore our new Cybersecurity Terms Glossary, explained by our experts.
Cybersecurity Terms Glossary
Smart grid security protects a digitised electricity network in which meters, distributed generation, and flexible demand are all controllable, and therefore all attackable at scale.

What Is Smart Grid Security?
A traditional electricity network moved power in one direction and measured it once a quarter. A smart grid measures continuously, accepts generation from rooftops and wind farms at the edge, and actively manages demand through storage, vehicle charging, and flexible loads. Smart grid security is the protection of that digitised network, and its defining characteristic is scale: the controllable population is counted in millions of devices rather than in hundreds of substations.
That changes the threat model fundamentally. Attacking a grid used to mean reaching a control centre. It can now also mean reaching a device fleet, because enough simultaneously switched load is itself a grid event.
The December 2015 attack on three Ukrainian distribution companies remains the reference case: operators watched their own cursors move as breakers were opened remotely, leaving around 225,000 customers without power, and the attackers also wiped workstations and flooded call centres to delay the response. In December 2016 Industroyer caused an outage in Kyiv by speaking grid protocols directly to equipment, and a revised version, Industroyer2, was deployed against a Ukrainian operator in April 2022. In 2024 the NCSC joined allied agencies in warning that the Volt Typhoon group had pre-positioned in critical infrastructure networks without any immediate destructive action, which is a different and more patient threat model.
Mass-device attacks remain largely theoretical in practice, but the arithmetic is uncomfortable: coordinated switching of a sufficiently large fleet of high-power loads would create a frequency disturbance, and academic work has examined the thresholds at which that becomes credible.
Britain built security into its smart metering programme from the start rather than retrofitting it. Meters communicate through a single national infrastructure operated by the Data Communications Company under the Smart Energy Code, commands are signed and checked, and devices are assessed against a dedicated assurance scheme before they can be installed. The architecture is more centralised than in most countries, which concentrates risk in the DCC while making control over commands considerably tighter than in a model where each supplier runs its own head-end.
Network operators sit within the Network and Information Systems Regulations 2018, with Ofgem as competent authority and assessment against the NCSC Cyber Assessment Framework. For the demand side, the Electric Vehicles (Smart Charge Points) Regulations 2021 set security requirements for chargepoints sold in Great Britain from December 2022, including protection of communications and a default randomised delay on charging to prevent synchronised demand surges. The government’s smart secure electricity systems programme is extending similar expectations to energy smart appliances and to the organisations that control them.
Our OT-SCADA Penetration Test covers distribution automation, metering head-end systems, and flexibility platforms, with testing scoped so that supply continuity is never at risk.
The remote disconnect capability exists, which is why it is the most tightly controlled function in the system. In Great Britain, commands travel through the national communications infrastructure with cryptographic signing and validation, and suppliers cannot send arbitrary instructions to arbitrary meters. The realistic concern is compromise of a supplier’s authorised access rather than an attacker reaching a meter directly.
It would require control of a very large, coordinated fleet of high-power loads, and the figures involved are substantial. The risk is taken seriously enough that regulation now addresses it: the UK requires randomised delays in electric vehicle chargepoints specifically to prevent synchronised demand surges, whether accidental or deliberate. Treat it as a credible long-term concern rather than an immediate one.
Protection schemes, synchrophasor measurement, and event correlation all depend on accurate, common time, usually taken from satellite signals that are unauthenticated and weak enough to be spoofed with modest equipment. Falsified time can cause protection to misoperate and makes forensic reconstruction unreliable. Use multiple independent sources, hold over locally, and alert when they disagree.
Coverage depends on size and role, and many sit below the thresholds that bring an operator into the NIS Regulations despite dispatching substantial capacity. Network operators and suppliers increasingly impose security requirements contractually to close the gap. An aggregator that can move tens of megawatts should expect to be assessed as infrastructure, whatever its formal designation.
You May Be Interested In These
We use a few cookies that are needed to make this website work, and they are always on. We would also like to set analytics cookies, to see which pages are useful; functional cookies, so that our live chat works; and advertising cookies, to measure our campaigns. We will not set any of those until you say yes, and you can change your mind at any time from the Cookie Settings link in the footer.
Choose the cookies you are happy for us to use. Strictly necessary cookies are always on; everything else is off until you turn it on.
These cookies keep the website working: they hold your security checks, your form submissions and the choice you make here. The site cannot run without them, so they are always on.
These let our live chat open and remember your conversation, and let the newsletter sign-up work. Switch them off and the chat window will not appear.
These tell us which pages are read and how people find us, so that we can improve the site. The reports are about groups of visitors, never about you personally.
These let us measure our advertising and show you our adverts on other websites, such as LinkedIn, Google and Meta. Switch them off and you will still see adverts, but they will be less relevant.