Explore our new Cybersecurity Terms Glossary, explained by our experts.
Cybersecurity Terms Glossary
Oil and gas OT security protects the control systems behind extraction, pipelines, terminals, and refining, where an incident can halt supply to a whole region or create a safety event.

What Is Oil and Gas OT Security?
Oil and gas operations run on control systems spread across enormous distances and hostile environments: wellhead controllers on an offshore platform, SCADA supervising thousands of kilometres of pipeline, tank gauging and custody transfer metering at a terminal, and a distributed control system running a refinery with a separate safety instrumented system watching over it. Oil and gas OT security is the protection of that estate, and its defining feature is that the consequence scale runs from lost production through environmental damage to loss of life.
The industry also has an unusually direct link between IT and physical delivery. The Colonial Pipeline incident of 7 May 2021 is the standing example: the DarkSide ransomware never reached the control network at all, but the company shut the pipeline down because its billing and scheduling systems were unavailable and it could not account for what it was moving. Fuel shortages followed across the eastern United States.
Four cases define how the sector thinks about this.
Shamoon, launched against Saudi Aramco on 15 August 2012, wiped around 30,000 workstations and forced the company back to typewriters and fax machines for weeks. It established that destructive malware against business IT can paralyse an energy company without touching a controller.
TRITON, also called TRISIS, was found at a Saudi petrochemical plant in 2017 after it tripped a Schneider Electric Triconex safety instrumented system. It is the first known malware written specifically to manipulate a safety system, and the implication was unmistakable: the layer that exists to prevent an explosion had itself become a target.
Colonial Pipeline showed the operational dependency between commercial IT and physical flow.
The European terminal attacks of early 2022, which hit Oiltanking and Mabanaft in Germany and operators in Belgium and the Netherlands, disrupted loading and barge scheduling at a string of ports in the same weeks, demonstrating how concentrated the fuel logistics chain is.
British operators face three overlapping regimes. Downstream oil and gas and parts of the midstream sit within the Network and Information Systems Regulations 2018 as essential services, assessed against the NCSC Cyber Assessment Framework by the relevant competent authority. Major hazard sites fall under the Control of Major Accident Hazards Regulations 2015, and the Health and Safety Executive’s operational guidance OG86 sets out how inspectors expect industrial automation and control system security to be handled, explicitly linking it to safety case obligations. Offshore installations add the Offshore Installations safety regime on top.
The practical significance of OG86 is that an HSE inspector can ask about cybersecurity as a safety matter, not merely as an information security matter, and expects to see it reflected in the safety management system. That is a stronger lever than most IT security teams realise they have.
Our OT-SCADA Penetration Test covers upstream, pipeline, and refinery environments with passive assessment first and tightly bounded active testing only where operations and safety allow it.
Because the commercial systems that measure, schedule, and bill product movement were unavailable, and the operator could not reliably account for what it was delivering or to whom. The pipeline could physically have run; the business could not run it safely or lawfully without those records. The case is the clearest demonstration that OT resilience includes the IT systems operations depends on.
As little as possible. Integration brings genuine operational benefits, including unified alarm management and easier proof testing, but TRITON showed what happens when a safety controller is reachable from a compromised engineering workstation. Where connectivity is required, it should be one-way where feasible, strictly brokered otherwise, with key switches enforced and every write to the controller alerted on.
Treat the link as untrusted and design for intermittency. Encrypt and authenticate everything crossing it, keep the platform able to operate autonomously when the link drops, and place remote access brokering onshore so sessions can be cut centrally. Also inventory what rides the same link: crew welfare networks and vendor equipment frequently share bandwidth with operational traffic.
It sets out how the Health and Safety Executive expects major hazard operators to manage cybersecurity for industrial automation and control systems, as part of the safety management arrangements rather than separately. It covers risk assessment, protection of safety-related systems, competence, and assurance, and gives inspectors a basis for questioning control system security during a COMAH inspection.
You May Be Interested In These
We use a few cookies that are needed to make this website work, and they are always on. We would also like to set analytics cookies, to see which pages are useful; functional cookies, so that our live chat works; and advertising cookies, to measure our campaigns. We will not set any of those until you say yes, and you can change your mind at any time from the Cookie Settings link in the footer.
Choose the cookies you are happy for us to use. Strictly necessary cookies are always on; everything else is off until you turn it on.
These cookies keep the website working: they hold your security checks, your form submissions and the choice you make here. The site cannot run without them, so they are always on.