Explore our new Cybersecurity Terms Glossary, explained by our experts.
Cybersecurity Terms Glossary
Physical access control systems govern entry to buildings and restricted areas using credentials, readers, controllers, and locks, and they are networked computers with all the exposure that implies.

What Are Physical Access Control Systems?
A physical access control system, usually shortened to PACS, is the set of components that decides whether a door opens: the credential a person carries, the reader that captures it, the controller that holds the access rules, the lock hardware that moves, and the management software where cardholders and permissions live. Access control cabinets in a data hall or a substation are, in every meaningful sense, networked computers that happen to be attached to doors.
That framing matters because PACS is usually procured by facilities, installed by a security integrator, and then never looked at again by the information security team. It often sits on a flat network with default credentials, running firmware that has not been touched since commissioning, and it controls the physical layer on which every other control depends.
Replace 125 kHz and MIFARE Classic with high-frequency credentials that perform mutual authentication, such as MIFARE DESFire EV3 or Seos, and provision them with site-specific keys rather than the integrator’s defaults. Replace Wiegand with OSDP v2 running Secure Channel, which encrypts and authenticates the reader-to-controller link and detects a disconnected reader. Put the PACS on its own segment with explicit rules, patch the controllers and head-end on a schedule, and feed the audit log into your SIEM so that a badge used in two buildings eleven minutes apart raises something.
Tie cardholder lifecycle to the identity management process that governs logical access. The classic failure is an employee who left in March still badging into a plant in August because the access control database is maintained by hand. This is the practical heart of physical and cyber convergence: the same joiners, movers, and leavers event should revoke both the account and the card.
Access control systems process personal data, and in many sites biometric templates, which are special category data under the UK GDPR requiring a lawful basis under Article 9 and a data protection impact assessment. The ICO’s 2024 enforcement action against Serco Leisure over fingerprint and facial recognition attendance monitoring turned on exactly that point: convenience is not a substitute for a genuine choice. Retention of door logs should be defined, documented, and short. Where a site holds CCTV alongside PACS, the Surveillance Camera Code of Practice remains relevant guidance for relevant authorities.
At Privia Security, our Social Engineering Services test the doors, the badges, and the people behind them together, because attackers rarely pick only one.
If it is a 125 kHz proximity card, yes, in under a second from a short distance, and the copy is indistinguishable to the reader. MIFARE Classic cards take a little longer but are also well within reach of inexpensive tooling. Cards using DESFire EV2 or EV3 with properly managed site keys are not practically cloneable.
OSDP is an open supervised device protocol standardised by the Security Industry Association that runs over RS-485. Version 2 adds Secure Channel, which encrypts and authenticates traffic between reader and controller and detects tampering or disconnection. Wiegand offers none of this, so an implant behind a reader can capture and replay credentials freely.
It should be on its own segment with controlled routes to only the services it needs, such as the head-end server, time synchronisation, and directory lookups. Putting it on the corporate LAN exposes the controllers to anything that reaches a user workstation, and putting it on the control network risks the opposite problem.
Almost always. Biometric data used to identify someone is special category data under the UK GDPR, so you need an Article 9 condition as well as a lawful basis, and processing of that kind on a large scale triggers the data protection impact assessment requirement. Offer a genuine non-biometric alternative that carries no disadvantage.
You May Be Interested In These
We use a few cookies that are needed to make this website work, and they are always on. We would also like to set analytics cookies, to see which pages are useful; functional cookies, so that our live chat works; and advertising cookies, to measure our campaigns. We will not set any of those until you say yes, and you can change your mind at any time from the Cookie Settings link in the footer.
Choose the cookies you are happy for us to use. Strictly necessary cookies are always on; everything else is off until you turn it on.
These cookies keep the website working: they hold your security checks, your form submissions and the choice you make here. The site cannot run without them, so they are always on.
These let our live chat open and remember your conversation, and let the newsletter sign-up work. Switch them off and the chat window will not appear.
These tell us which pages are read and how people find us, so that we can improve the site. The reports are about groups of visitors, never about you personally.
These let us measure our advertising and show you our adverts on other websites, such as LinkedIn, Google and Meta. Switch them off and you will still see adverts, but they will be less relevant.